کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
184547 459578 2015 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A novel sensing platform based on ionic liquid integrated carboxylic-functionalized graphene oxide nanosheets for honokiol determination
ترجمه فارسی عنوان
یک پلت فرم سنجش جدید مبتنی بر نانوساختار اکسید گرافن کربوکسیل-کارکردی یکپارچه مایع یونی برای تعیین هوشیاری
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
چکیده انگلیسی


• Piperidinium based ionic liquid bearing pyrrole was synthesized.
• Ionic liquid integrated graphene oxide nanocompisite was fabricated.
• Polymerized ionic liquid-graphene oxide film electrode was prepared.
• The film electrode exhibits high sensitivity towards honokiol and magnolol.
• Stimulate determination of honokiol and magnolol was fulfilled.

A novel ionic liquid, 4-hydroxy-1-methyl-[1-(3-pyrrolyl-propyl)]-piperidinium bromide, was synthesized and characterized. Carboxylic-functionalized graphene oxide nanosheets were modified with this ionic liquid to fabricate a nanocomposite which was denoted as GrO-COO-IL. Characterizations of FTIR, X-ray photoelectron spectroscopy, Raman spectroscopy and transmission electron microscopy confirmed the successful conjunction of these two components. GrO-COO-IL nanocomposites were homogeneously dispersed with utralpure water, and were then coated onto glassy carbon electrode surface. Followed by cyclic voltammetric scanning, a graphene oxide-polymerized ionic liquid film modified electrode (GrO-COO-Poly-IL/GCE) was prepared, and was studied with electrochemical impedance spectroscopy and scanning electron microscope. It was found that both honokiol and magnolol exhibit sensitive voltammetric response at the GrO-COO-Poly-IL/GCE. Simultaneous assay of honokiol and magnolol was realized with differential pulse voltametry. In the presence of magnolol, the oxidation peak current was linearly related to honokiol concentration in the range of 1.0 × 10−8 ∼ 1.0 × 10−5 mol L−1 with a detection limit of 1.53 × 10−9 mol L−1 (S/N = 3). Meanwhile, in the presence of honokiol, a linear relationship between the oxidation peak current and magnolol concentration was found from 7.0 × 10−8 to 1.0 × 10−5 mol L−1. The detection limit is calculated to be 8.27 × 10 −9 mol L−1 (S/N = 3). In addition, GrO-COO-Poly-IL/GCE was successfully used for determination of honokiol in the traditional Chinese medicine, and was demonstrated to be an effective and sensitive method.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Electrochimica Acta - Volume 155, 10 February 2015, Pages 45–53
نویسندگان
, , , , , , , ,