کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
185030 459589 2014 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Performance Evaluation of Two-Stage Electrokinetic Washing as Soil Remediation Method for Lead Removal using Different Wash Solutions
ترجمه فارسی عنوان
بررسی عملکرد شستشوی الکتروکنتیک دو مرحله ای به عنوان روش اصلاح خاک برای حذف سرب با استفاده از راه حل های مختلف شستشو
کلمات کلیدی
شستشوی الکتروکینتیک دو مرحله ای، درمان خاک، رهبری، راه حل شستشو مکانیسم های حمل و نقل
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
چکیده انگلیسی


• Incorporation of electrokinetic process as another driving force in soil washing
• Electrokinetic washing could provided >90% Pb removal even with soil: wash solution ratio of 1 g: <1 mL
• Two-stage electrokinetic washing shows better Pb removal than normal soil washing
• Soil pH and current are more important than complexation in the removal process
• Transport mechanisms under each wash solution are discussed

The study explores the application of a two-stage electrokinetic washing system on remediation of lead (Pb) contaminated soil. The process involved an initial soil washing, followed by an electrokinetic process. The use of electrokinetic process in soil washing not only provided additional driving force for transporting the desorbed Pb away from the soil but also reduced the high usage of wash solution. In this study, the effect of NaNO3, HNO3, citric acid and EDTA as wash solutions on two-stage electrokinetic washing system were evaluated. The results revealed that a two-stage electrokinetic washing process enhanced Pb removal efficiency by 2.52-9.08% and 4.98-20.45% in comparison to a normal electrokinetic process and normal washing process, respectively. Low pH and adequate current were the most important criteria in the removal process as they provided superior desorption and transport properties. The effect of chelating by EDTA was less dominant as it delayed the removal process by forming a transport loop in anode region between Pb ion and complexes. HNO3 was not suitable as wash solution in electrokinetic washing in spite of offering highest removal efficiency as it caused pH fluctuation in the cathode chamber, corroded graphite anode and showed high power consumption. In contrast, citric acid not only yielded high Pb removal efficiency with low power consumption but also maintained a low soil: solution ratio of 1 g: <1 mL, stable pH and electrode integrity. Possible transport mechanisms for Pb under each wash solution are also discussed in this work.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Electrochimica Acta - Volume 147, 20 November 2014, Pages 9–18
نویسندگان
, , ,