کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
185387 459597 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Synthesis, characterization and application of novel lead imprinted polymer nanoparticles as a high selective electrochemical sensor for ultra-trace determination of lead ions in complex matrixes
ترجمه فارسی عنوان
سنتز، خصوصی سازی و کاربرد نانوذرات پلیمری با نام تجاری جدید به عنوان یک سنسور الکتروشیمیایی انتخابی برای تعیین فوق العاده ردیابی یون سرب در ماتریس های پیچیده
کلمات کلیدی
الکترود گذشته کربن، سرب حاوی نانوذرات پلیمری است. ولتامتری سدی آنالوگ پالس دیفرانسیل، نمونه های آب محیطی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
چکیده انگلیسی

We report on the design of a lead(II)-selective electrode based on the use of lead(II) imprinted polymer nanoparticles (IP-NPs), and its application for the differential pulse voltammetry determination of lead ions. The IP-NPs were obtained by precipitation polymerization of 4-vinylpyridine (the functional monomer), ethylene glycol dimethacrylate (the cross-linker), 2,2’-azobisisobutyronitrile (the initiator), 4-(2-pyridylazo)resorcinol (the lead-binding ligand), and lead ions (the template ion) in acetonitrile solution. After polymerization, the Pb(II) in the polymer nanoparticles were leached out with dilute hydrochloric acid to create cavities for hosting Pb(II). The new sensor showed high selectivity for lead ions in the presence of common potential interferences according to the specific recognition nature of the synthesized material. A carbon paste electrode was modified with the IP-NPs, and differential pulse stripping voltammetry was applied as the detection technique after open-circuit sorption of Pb(II) ions and its reduction to the metallic form. An explicit difference in the response was observed between the electrodes modified with IP-NPs and electrodes modified with non-IP-NPs. The modified electrode responds to Pb(II) was linear in the 0.1 nM to 10 nM (with sensitivity of 49.179 nA/nM) and in the 10 nM to 10 μM (with sensitivity of 30.305 μA/μM) concentration range. The limit of detection (LOD) of the sensor was 30 pM (at S/N =3). The sensor was successfully applied to the trace determination of Pb(II) in spiked environmental water samples.

A selective electrode, based on lead ion imprinted polymer nanoparticles (IIP), and its application for the determination of lead ions in the real samples is introduced. The designed modified electrode was revealed linear responses in the ranges of 1.0 × 10−10 - 1.0 × 10−8 mol L−1 and 1.0 × 10−8 - 1.0 × 10−6 mol L−1 with a limit of detection (LOD) of 3.0 × 10−11 mol L−1 (S/N =3).Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Electrochimica Acta - Volume 136, 1 August 2014, Pages 59–65
نویسندگان
, , , , , ,