Image-Guided Stereotactic Body Radiotherapy for Lung Tumors Using BodyLoc With Tomotherapy: Clinical Implementation and Set-Up Accuracy
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
تشعشع
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
We investigated the use of a BodyLoc immobilization and stereotactic localization device combined with TomoTherapy megavoltage CT (MVCT) in lung stereotactic body radiotherapy (SBRT) to reduce set-up uncertainty and treatment time. Eight patients treated with 3-5 fractions of SBRT were retrospectively analyzed. A BodyLoc localizer was used in both CT simulation for localization and the initial patient treatment set-up. Patients were immobilized with a vacuum cushion on the back and a thermoplastic body cast on the anterior body. Pretreatment MVCT from the TomoTherapy unit was fused with the planning kilovoltage CT (KVCT) before each fraction of treatment to determine interfractional set-up error. The comparison of two MVCTs during a fraction of treatment resulted in the intrafractional uncertainty of the treatment. A total of 224 target isocenter shifts were analyzed to assess these inter- and intrafractional tumor motions. We found that for interfractional shifts, the mean set-up errors and standard deviations were -1.1 ± 2.8 mm, -2.5 ± 8.7 mm, and 4.1 ± 2.6 mm, for lateral, longitudinal, and vertical variation, respectively; the mean setup rotational variation was -0.3 ± 0.7°; and the maximum motion was 13.5 mm in the longitudinal direction. For intrafractional shifts, the mean set-up errors and standard deviations were -0.1 ± 0.7 mm, -0.3 ± 2.0 mm, and 0.5 ± 1.1 mm for the lateral, longitudinal, and vertical shifts, respectively; the mean rotational variation was 0.1 ± 0.2°; and the maximum motion was 3.8 mm in the longitudinal direction. There was no correlation among patient characteristics, set-up uncertainties, and isocenter shifts, and the interfractional set-up uncertainties were larger than the intrafractional isocenter shift. The results of this study suggested that image-guided stereotactic body radiotherapy using the BodyLoc immobilization system with TomoTherapy can improve treatment accuracy.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Medical Dosimetry - Volume 35, Issue 1, Spring 2010, Pages 12-18
Journal: Medical Dosimetry - Volume 35, Issue 1, Spring 2010, Pages 12-18
نویسندگان
Jining Ph.D., Barry M.D., Kelly M.D., Mark M.S., Brian M.B.A., Ding-Yu Ph.D., Yeh-Chi Ph.D.,