کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1882249 1043211 2016 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Influence of beam incidence and irradiation parameters on stray neutron doses to healthy organs of pediatric patients treated for an intracranial tumor with passive scattering proton therapy
ترجمه فارسی عنوان
تأثیر پارامترهای برانگیختگی و پارامترهای تابش در دوزهای نوترونی منجر به ارگانهای سالم در کودکان مبتلا به تومور داخل جمجمه با پراکنش منفرد پروتون درمانی
کلمات کلیدی
پروتون درمانی، دوزهای نوترونی منفرد، درمان های داخل چرکی، برانگیختگی پرتو
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
چکیده انگلیسی


• MC calculations were used to assess neutron doses to healthy organs.
• Lateral incidences induce more neutron doses than the anterior–superior incidence.
• Impact of some irradiation parameters on neutron doses changes with beam incidence.
• Investigations on internal neutron fluence and doses were carried out.
• Beam incidence impacts the fluence and energy of neutrons reaching the patient.

PurposeIn scattering proton therapy, the beam incidence, i.e. the patient’s orientation with respect to the beam axis, can significantly influence stray neutron doses although it is almost not documented in the literature.MethodsMCNPX calculations were carried out to estimate stray neutron doses to 25 healthy organs of a 10-year-old female phantom treated for an intracranial tumor. Two beam incidences were considered in this article, namely a superior (SUP) field and a right lateral (RLAT) field. For both fields, a parametric study was performed varying proton beam energy, modulation width, collimator aperture and thickness, compensator thickness and air gap size.ResultsUsing a standard beam line configuration for a craniopharyngioma treatment, neutron absorbed doses per therapeutic dose of 63 μGy Gy−1 and 149 μGy Gy−1 were found at the heart for the SUP and the RLAT fields, respectively. This dose discrepancy was explained by the different patient’s orientations leading to changes in the distance between organs and the final collimator where external neutrons are mainly produced. Moreover, investigations on neutron spectral fluence at the heart showed that the number of neutrons was 2.5 times higher for the RLAT field compared against the SUP field. Finally, the influence of some irradiation parameters on neutron doses was found to be different according to the beam incidence.ConclusionBeam incidence was thus found to induce large variations in stray neutron doses, proving that this parameter could be optimized to enhance the radiation protection of the patient.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Physica Medica - Volume 32, Issue 4, April 2016, Pages 590–599
نویسندگان
, , , , , , , , ,