کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1968905 1538875 2014 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The evaluation and comparison of consecutive high speed centrifugation and LipoClear® reagent for lipemia removal
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی زیست شیمی
پیش نمایش صفحه اول مقاله
The evaluation and comparison of consecutive high speed centrifugation and LipoClear® reagent for lipemia removal
چکیده انگلیسی


• Lipemic samples cause a considerable problem in everyday practice
• High speed centrifugation and Lipoclear® reagent for lipemia removal were evaluated
• 26 analytes were determined
• Lipoclear® is not suitable for lipemia removal for determination of 13 analytes
• High speed centrifugation should be considered for lipemia removal instead

BackgroundThe aim of this study was to evaluate and compare the efficiency of high speed centrifugation and LipoClear® reagent for lipemia removal in plasma samples spiked with Intralipid®, for 26 biochemistry analytes.Materials and methodsA plasma pool was collected. Aliquots of the pool were spiked with Intralipid® (final concentrations of 300 mg/dL and 500 mg/dL Intralipid®). The lipemia was removed from the aliquots by high speed centrifugation or LipoClear® reagent. 26 analytes were determined in native, lipemic plasma and in samples after lipemia removal. The bias from the concentration in the native sample was calculated for each parameter for Intralipid® concentrations, 300 and 500 mg/dL of Intralipid®, respectively. Also, the recovery for each parameter after processing the samples using high speed centrifugation and LipoClear® was calculated. The biases and test recoveries were compared with the desirable specification for imprecision (DSI) according to Ricos available at the Wesgard's website. The bias and recovery for procalcitonin were compared with DSI according to Barassi and colleagues.ResultsThe bias of the spiked samples exceeded the DSI at 300 mg/L Intralipid® for creatinine, glucose, total protein, iron and albumin; and for all previously mentioned parameters including CK-MB, sodium, potassium, chlorides, magnesium and ALP at concentration of 500 mg/L Intralipid®. For the test recovery the DSI criteria were not met for calcium, total protein, sodium and chlorides after high speed centrifugation and for glucose, calcium, phosphates, magnesium, sodium, potassium, chlorides, ALP, GGT, CK-MB, total protein, albumin and troponin T after using LipoClear®.ConclusionsLipoClear® is not suitable for lipemia removal from samples designated for glucose, sodium, potassium, chlorides, phosphates, magnesium, CK-MB, ALP, GGT, total protein, albumin, CRP and troponin T measurements. High speed centrifugation should be used for lipemia removal instead for glucose, potassium, phosphates, magnesium, CK-MB, ALP, GGT, albumin, CRP and TnT measurements.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Biochemistry - Volume 47, Issues 4–5, March 2014, Pages 309–314
نویسندگان
, , ,