کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
214519 1425858 2006 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Continuous air rate measurement in flotation cells: Some fundamental considerations
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Continuous air rate measurement in flotation cells: Some fundamental considerations
چکیده انگلیسی

A robust and reliable sensor to measure gas (air) superficial velocity (Jg) continuously in flotation systems is introduced. It is based on the sampling of bubbles by buoyancy with the accumulating air allowed to exit through an orifice. At steady state, pressure drop is measured and related to the Jg by prior calibration. The continuous device is readily automated and extended to a multi-unit set-up. The sensor and data collections are described. The governing gas flow equation and models of the dynamic response to air flow rate set point change and fluctuations in froth depth are derived. Model predictions are confirmed against plant data. By taking a moving average, the Jg remains valid in the face of typical plant disturbances.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Mineral Processing - Volume 81, Issue 2, November 2006, Pages 85–92