کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
219757 463295 2010 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A formal scan rate in staircase and square-wave voltammetry
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
A formal scan rate in staircase and square-wave voltammetry
چکیده انگلیسی

Because of the fact that real measurements are sometimes described in terms of the (formal) scan rate, the functional relationships between this parameter and the peak current in staircase (SCV) and square-wave voltammetry (SWV) were investigated theoretically. The real SCV peak current is proportional to the square-root of the formal scan rate, v, and inversely proportional to ΔE0.0541: −ip = 0.1453nFScox∗(D/π)½v½ΔE−0.0541. In SWV of a reversible electrode reaction the net peak current depends primarily on the frequency, while the influence of the formal scan rate is of minor importance: Δip = nFScox∗D½(0.7339f½ + 0.0026ΔE0.3118v½). On the other hand, in SWV of a totally irreversible electrode reaction, the real net peak current is a stronger function of the formal scan rate: Δip = 0.0942nFScox∗D½ΔE−0.11v½. Experimental results, obtained in perchlorate solutions of Eu3+, are in relatively good agreement with the theory.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Electroanalytical Chemistry - Volume 645, Issue 2, 1 July 2010, Pages 103–108
نویسندگان
, , ,