کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2424384 1552956 2008 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Reducing inter-operator variation in disc diffusion assays by the inclusion of internal controls in a standard susceptibility test protocol
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک علوم آبزیان
پیش نمایش صفحه اول مقاله
Reducing inter-operator variation in disc diffusion assays by the inclusion of internal controls in a standard susceptibility test protocol
چکیده انگلیسی

A series of experiments were performed to investigate the impact of the inclusion of internal controls on the inter-operator precision of disc diffusion assays. The susceptibilities of 98 strains of Aeromonas salmonicida to florfenicol were determined by ten untrained operators using two disc diffusion test protocols. One was the Clinical Laboratory and Standard Institute's M42-A protocol which, in its quality control requirements, employs external controls. The second was a version of the protocol published by Alderman and Smith in 2001 that had been modified to include internal controls. The only alteration of the protocol required by this modification was the inoculation of the control strain onto one half of an assay plate and the test strain on the other and the placing of the discs between the areas inoculated with the two strains. The output data of the modified, internal control, method was the difference in the radii of the control and test strains.There was significant inter-operator variation in the data generated using the M42-A protocols. For replicate (n = 9–11) measurements of the control strain, the mean of the values generated by the untrained operators ranged from 33.5 mm–45.1 mm. The mean zone sizes for the 9–11 wild-type test strains each operator tested varied from 35.0 mm–45.2 mm. The extent of inter-operator variation was significantly reduced when the protocol incorporating internal controls was used. Using this modified protocol, the range of the operator means for the difference in radii for wild-type strains was 0.2 mm to 1.4 mm.It is argued that the modification of a standard protocol to include internal controls would allow the classification of a clinical isolate using a single plate and that this would have advantages for laboratories handling a limited number of strains a year. This initial investigation of the performance characteristics of such a modified protocol suggests that more extensive studies are warranted.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Aquaculture - Volume 285, Issues 1–4, 7 December 2008, Pages 273–276
نویسندگان
, , ,