The Development of Heated Tip Force-Distance Measurements as a Novel Approach to Site-Specific Characterization of Pharmaceutical Materials
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت
داروسازی، سم شناسی و علوم دارویی
اکتشاف دارویی
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: The Development of Heated Tip Force-Distance Measurements as a Novel Approach to Site-Specific Characterization of Pharmaceutical Materials The Development of Heated Tip Force-Distance Measurements as a Novel Approach to Site-Specific Characterization of Pharmaceutical Materials](/preview/png/2485534.png)
چکیده انگلیسی
The study describes the development of a novel approach to surface analysis whereby thermal probes are used to perform scanning probe microscopy pull-off force measurements as a function of tip rather than sample temperature. The initial impetus for the investigation was the study of a poorly understood phenomenon associated with microthermal analysis (MTA) whereby the thermal probe is pulled into the surface of a sample following temperature-induced softening. Localized thermomechanical analysis experiments were performed on a range of pharmaceutical materials using TA Instruments 2990 Microthermal Analyzer equipped with a TM Microscopes Explorer atomic force microscope. The system was then interfaced with a second instrument to allow simultaneous probe temperature control and pull-off force measurement. It was found that the pull-in effect is due to the adhesion of the probe to the material at elevated (softening) temperatures. However, it was also noted that for paracetamol tablets the pull-off force increased at temperatures well below the softening associated with melting. This behavior was ascribed to surface polymorphic changes caused by the compression process. The temperature-controlled pull-off force method therefore represents a novel and potentially widely applicable means of detecting surface changes that are not easily observed using isothermal pull-off force measurements or indeed standard MTA studies.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical Sciences - Volume 97, Issue 7, July 2008, Pages 2768-2779
Journal: Journal of Pharmaceutical Sciences - Volume 97, Issue 7, July 2008, Pages 2768-2779
نویسندگان
Ljiljana Harding, Mike Reading, Duncan Q.M. Craig,