کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2567621 1128339 2008 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparable long-term safety and efficacy of a novel budesonide/formoterol pressurized metered-dose inhaler versus budesonide/formoterol Turbuhaler® in adolescents and adults with asthma
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی ریوی و تنفسی
پیش نمایش صفحه اول مقاله
Comparable long-term safety and efficacy of a novel budesonide/formoterol pressurized metered-dose inhaler versus budesonide/formoterol Turbuhaler® in adolescents and adults with asthma
چکیده انگلیسی

Budesonide/formoterol in one inhaler is an established therapy for asthma and chronic obstructive pulmonary disease. The long-term safety and efficacy profile of a novel hydrofluoroalkane (HFA) pressurized metered-dose inhaler (pMDI) formulation of budesonide/formoterol was compared with that of budesonide/formoterol in a dry powder inhaler (DPI; Turbuhaler®). This multinational, 52-week, randomized, open, parallel-group study included patients aged ⩾12 years with asthma who had a forced expiratory volume in 1 s (FEV1)⩾50% of predicted normal; all patients used inhaled corticosteroids (400–1200 μg/day) and needed additional short-acting β2-agonist therapy. Patients were randomized to receive budesonide/formoterol pMDI or DPI 160/4.5 μg, two inhalations twice daily. Safety endpoints included assessment of adverse events and laboratory parameters. Efficacy endpoints included change from baseline in FEV1 and time to first severe asthma exacerbation. Overall, 673 patients (446 pMDI, 227 DPI) were included. There were no clinically significant differences between treatment groups in the nature, incidence or severity of adverse events or laboratory parameters. The number of patients experiencing adverse events was comparable in the pMDI (332/446 [74%]) and DPI (175/227 [77%]) groups; the most commonly reported adverse event was upper respiratory tract infection. The proportion of patients discontinuing as a result of adverse events was low in both groups (pMDI 12/446 [3%], DPI 2/227 [1%]). Lung function was improved to a similar extent in both groups and there was no detectable difference in time to first severe asthma exacerbation. The novel HFA pMDI formulation of budesonide/formoterol is an equally well tolerated and effective treatment for adults and adolescents with asthma as the budesonide/formoterol DPI.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Pulmonary Pharmacology & Therapeutics - Volume 21, Issue 1, February 2008, Pages 32–39
نویسندگان
, , , , ,