کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
267836 504416 2011 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Performance of axially restrained concrete encased steel composite columns at elevated temperatures
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات مهندسی ژئوتکنیک و زمین شناسی مهندسی
پیش نمایش صفحه اول مقاله
Performance of axially restrained concrete encased steel composite columns at elevated temperatures
چکیده انگلیسی

The structural performance of axially restrained concrete encased steel composite columns at elevated temperatures is investigated in this study. An efficient nonlinear 3-D finite element model was presented for the analysis of the pin-ended axially loaded columns. The restraint ratios varied from 20% to 100% of the axial stiffness of the composite columns at ambient temperature. The finite element model was verified against published test results on axially restrained concrete encased steel composite columns at elevated temperatures. The columns investigated had different cross-sectional dimensions, different coarse aggregates and different load ratios during fire. The nonlinear material properties of steel, concrete, longitudinal and transverse reinforcement bars as well as the effect of concrete confinement at ambient and elevated temperatures were considered in the finite element model. The interface between the steel section and concrete, the longitudinal and transverse reinforcement bars, and the reinforcement bars and concrete were also considered allowing the bond behaviour to be modelled and the different components to retain its profile during the deformation of the column. The initial overall geometric imperfection was carefully included in the model. The time–temperature relationships, deformed shapes at failure, time–axial displacement relationships, failure modes and fire resistances of the columns were evaluated by the finite element model and compared well against test results. Furthermore, the variables that influence the fire resistance and behaviour of the axially restrained composite columns comprising different axial restraint ratios, different load ratios during fire, different coarse aggregates and different slenderness ratios were investigated in a parametric study. It is shown that axially restrained composite columns behave differently in fire compared to the unrestrained columns since the typical “runaway” failure was not predicted from the finite element analysis. The fire resistances of the composite columns obtained from the finite element analysis were compared with the design values obtained from the Eurocode 4 for composite columns at elevated temperatures. It is shown that the EC4 is generally conservative for all the axially restrained concrete encased steel composite columns, except for some columns with higher load and slenderness ratios.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Structures - Volume 33, Issue 1, January 2011, Pages 245–254
نویسندگان
, ,