Validity and reliability of Polar® RS800CX heart rate monitor, measuring heart rate in dogs during standing position and at trot on a treadmill
چکیده انگلیسی


• Polar® RS800CX seemed to over- and underestimate BPM.
• Polar® RS800CX reliably measures BPM in the dogs studied.
• Criterion validity and instrument reliability were excellent.

The aim of the present study was to assess criterion validity, and relative and absolute reliability of Polar® RS800CX heart rate monitor, compared to simultaneously recorded electrocardiogram (ECG) data, in measuring heart rate of dogs during standing position and at trot on a treadmill.MethodsHeart beats from Polar® RS800CX and Cardiostore ECG were recorded simultaneously during seven continuous minutes in standing position and at trot, in 10 adult healthy dogs. Polar® data was statistically compared to ECG data for a variety of mean beats per minute (BPM), standard deviation and confidence interval. Criterion validity was calculated by Pearson product moment correlation method and intraclass correlation coefficient (ICC2.1). Relative and absolute reliability were calculated by ICC2.1, the Bland and Altman analysis and standard error of measurement (SEM and SEM%).ResultsThe correlation, criterion validity, between Polar® and ECG data in standing position was r = 0.99 (p < 0.0005) and at trot r = 0.97 (p < 0.0005). Polar® data was not significantly different from ECG data. Mean difference between ECG and uncorrected Polar® data was − 0.6 BPM in standing position and − 0.6 BPM at trot. Polar® was over- and underestimating ECG data. SEM and SEM% in standing were ± 2.6 BPM and 3.0%, at trot ± 3.8 BPM and 3.1%, indicating that measurement errors were low.ConclusionThis study showed that the criterion validity and the instrument reliability were excellent in Polar® RS800CX heart rate measuring system. The equipment seemed to be valid and reliable in measuring BPM in the dogs studied during submaximal cardiovascular conditions such as in standing position and at trot on a treadmill.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Physiology & Behavior - Volumes 114–115, 10 April 2013, Pages 1–5
نویسندگان
, , , ,