کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2945860 1577162 2013 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial Fibrillation : First Results of the North American Arctic Front (STOP AF) Pivotal Trial
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial Fibrillation : First Results of the North American Arctic Front (STOP AF) Pivotal Trial
چکیده انگلیسی

ObjectivesThis study sought to assess the safety and effectiveness of a novel cryoballoon ablation technology designed to achieve single-delivery pulmonary vein (PV) isolation.BackgroundStandard radiofrequency ablation is effective in eliminating atrial fibrillation (AF) but requires multiple lesion delivery at the risk of significant complications.MethodsPatients with documented symptomatic paroxysmal AF and previously failed therapy with ≥1 membrane active antiarrhythmic drug underwent 2:1 randomization to either cryoballoon ablation (n = 163) or drug therapy (n = 82). A 90-day blanking period allowed for optimization of antiarrhythmic drug therapy and reablation if necessary. Effectiveness of the cryoablation procedure versus drug therapy was determined at 12 months.ResultsPatients had highly symptomatic AF (78% paroxysmal, 22% early persistent) and experienced failure of at least one antiarrhythmic drug. Cryoablation produced acute isolation of three or more PVs in 98.2% and all four PVs in 97.6% of patients. PVs isolation was achieved with the balloon catheter alone in 83%. At 12 months, treatment success was 69.9% (114 of 163) of cryoblation patients compared with 7.3% of antiarrhythmic drug patients (absolute difference, 62.6% [p < 0.001]). Sixty-five (79%) drug-treated patients crossed over to cryoablation during 12 months of study follow-up due to recurrent, symptomatic AF, constituting drug treatment failure. There were 7 of the resulting 228 cryoablated patients (3.1%) with a >75% reduction in PV area during 12 months of follow-up. Twenty-nine of 259 procedures (11.2%) were associated with phrenic nerve palsy as determined by radiographic screening; 25 of these had resolved by 12 months. Cryoablation patients had significantly improved symptoms at 12 months.ConclusionsThe STOP AF trial demonstrated that cryoballoon ablation is a safe and effective alternative to antiarrhythmic medication for the treatment of patients with symptomatic paroxysmal AF, for whom at least one antiarrhythmic drug has failed, with risks within accepted standards for ablation therapy. (A Clinical Study of the Arctic Front Cryoablation Balloon for the Treatment of Paroxysmal Atrial Fibrillation [Stop AF]; NCT00523978)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 61, Issue 16, 23 April 2013, Pages 1713–1723
نویسندگان
, , , , , , , , , , , ,