کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2945949 1577164 2013 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Prevention of Sudden Cardiac Death With Implantable Cardioverter-Defibrillators in Children and Adolescents With Hypertrophic Cardiomyopathy
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Prevention of Sudden Cardiac Death With Implantable Cardioverter-Defibrillators in Children and Adolescents With Hypertrophic Cardiomyopathy
چکیده انگلیسی

ObjectivesThe aim of this study was to determine the efficacy of implantable cardioverter-defibrillators (ICDs) in children and adolescents with hypertrophic cardiomyopathy (HCM).BackgroundHCM is the most common cause of sudden death in the young. The availability of ICDs over the past decade for HCM has demonstrated the potential for sudden death prevention, predominantly in adult patients.MethodsA multicenter international registry of ICDs implanted (1987 to 2011) in 224 unrelated children and adolescents with HCM judged at high risk for sudden death was assembled. Patients received ICDs for primary (n = 188) or secondary (n = 36) prevention after undergoing evaluation at 22 referral and nonreferral institutions in the United States, Canada, Europe, and Australia.ResultsDefibrillators were activated appropriately to terminate ventricular tachycardia or ventricular fibrillation in 43 of 224 patients (19%) over a mean of 4.3 ± 3.3 years. ICD intervention rates were 4.5% per year overall, 14.0% per year for secondary prevention after cardiac arrest, and 3.1% per year for primary prevention on the basis of risk factors (5-year cumulative probability 17%). The mean time from implantation to first appropriate discharge was 2.9 ± 2.7 years (range to 8.6 years). The primary prevention discharge rate terminating ventricular tachycardia or ventricular fibrillation was the same in patients who underwent implantation for 1, 2, or ≥3 risk factors (12 of 88 [14%], 10 of 71 [14%], and 4 of 29 [14%], respectively, p = 1.00). Extreme left ventricular hypertrophy was the most common risk factor present (alone or in combination with other markers) in patients experiencing primary prevention interventions (17 of 26 [65%]). ICD-related complications, particularly inappropriate shocks and lead malfunction, occurred in 91 patients (41%) at 17 ± 5 years of age.ConclusionsIn a high-risk pediatric HCM cohort, ICD interventions terminating life-threatening ventricular tachyarrhythmias were frequent. Extreme left ventricular hypertrophy was most frequently associated with appropriate interventions. The rate of device complications adds a measure of complexity to ICD decisions in this age group.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 61, Issue 14, 9 April 2013, Pages 1527–1535
نویسندگان
, , , , , , , , , , , , ,