کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3335204 1213524 2013 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Microbial contamination of hematopoietic progenitor cell products
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی هماتولوژی
پیش نمایش صفحه اول مقاله
Microbial contamination of hematopoietic progenitor cell products
چکیده انگلیسی

IntroductionMicrobial screening for contamination is a part of hematopoietic progenitor cell (HPC) collection and infusion procedure. We aimed to find out our microbial contamination rates during collection, processing and infusion steps of HPC products. We also evaluated the clinical course of patients who received contaminated HPC products.Patients-methodsWe retrospectively analyzed microbial contamination records of HPC grafts between 2010 and 2012. HPC products of autologous donors were evaluated for contamination at three steps: at the end of mobilization, following processing with DMSO and just before stem cell infusion. Grafts of allogeneic donors were assessed only before HPC transplantation (HCT). Microbiological analysis of HPC samples were performed with an automated system (BacT/Alert®).ResultDuring the study period a total of 492 mobilization procedures were performed on 329 (214 autologous and 115 allogeneic) donors. Bacterial contamination has been detected in 103 of 1630 samples (6%). Ninety-seven out of 1162 blood samples (8%) from 265 patients who were treated with HCT were contaminated. Forty-six patients (41 autologous and 5 allogeneic) were transplanted with contaminated HPC products. During HCT 42 patients experienced febrile neutropenic attack and 34 of them had positive blood culture results. In none of these 34 patients the isolated pathogens were the same organisms with those found in the final contaminated stem cell product before stem cell infusion. None of the patients who received contaminated products died because of sepsis within the posttransplant 30 days. There was no significant difference between patients who received contaminated and non-contaminated products in terms of the first day of fever, duration of fever, engraftment kinetics and duration of hospitalization.ConclusionOur results suggest that microbial contamination of HPC products is an issue to be prevented, although it may not have a major impact on the general success of HCT.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Transfusion and Apheresis Science - Volume 48, Issue 3, June 2013, Pages 403–406
نویسندگان
, , , , , , , , , ,