کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3406671 1593484 2013 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of a virus concentration method using lanthanum-based chemical flocculation coupled with modified membrane filtration procedures
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی ویروس شناسی
پیش نمایش صفحه اول مقاله
Development of a virus concentration method using lanthanum-based chemical flocculation coupled with modified membrane filtration procedures
چکیده انگلیسی


• A lanthanum-based concentration method coupled with membrane filtration was developed.
• The results from the new method were compared with those of EPA direct filtration method.
• There was no or low detection of viruses through NanoCeram- or 1MDS-based direct filtration.
• The new method resulted in an overall concentration of viral particles in 40-L water by 20,000-fold.
• The detection efficiencies were 20.6% and 19.5% for MS2 and adenovirus, respectively, by the new method.

Direct membrane filtration is often used to concentrate viruses in water but it may suffer from severe membrane fouling and clogging. Here, a lanthanum-based flocculation method coupled with modified membrane filtration procedures was developed and evaluated to detect viruses in large volume (40 L) water samples. The lanthanum-based flocculation method could easily reduce the water sample volume by a factor of 40. Additional volume reduction was achieved by a two-step membrane filtration approach. First, selected membrane filters (including 1MDS electropositive filters and nitrocellulose electronegative filters-Millipore HATF filters) were used to reduce water sample volume further and compare their efficiencies in virus recovery. The Mg2+-modified HATF membrane performed better on MS2 retention with an average virus recovery of 83.4% (±4.5% [standard deviation]). After HATF membrane filtration and elution, centrifugal ultrafiltration through a 30 kDa cut-off membrane resulted in an overall concentration factor of 20,000. Results from the infectivity assay showed that the MS2 recovery efficiencies from the NanoCeram- and 1MDS-based direct filtration and the lanthanum-based concentration coupled with the modified filtration procedure were 10.1% (±1.0%), 3.3% (±0.1%), and 17.5% (±1.1%), respectively. Results from the PCR analysis showed that the virus recoveries of the lanthanum-based method were 20.6% (±2.9%) and 19.5% (±3.4%) for MS2 and adenovirus, respectively, while no adenovirus could be detected through the NanoCeram- and 1MDS-based direct filtration. The lanthanum-based concentration method coupled with modified membrane filtration procedures is therefore a promising method for detecting waterborne viruses.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Virological Methods - Volume 190, Issues 1–2, June 2013, Pages 41–48
نویسندگان
, , , , ,