کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3987471 1601462 2008 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Radiofrequency hepatic ablation with internally cooled electrodes and hybrid applicators with distant saline infusion using an in vivo porcine model
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی تومور شناسی
پیش نمایش صفحه اول مقاله
Radiofrequency hepatic ablation with internally cooled electrodes and hybrid applicators with distant saline infusion using an in vivo porcine model
چکیده انگلیسی

AimsRadiofrequency ablation (RFA) of tumors by means of internally cooled (ICE) or multitined expandable electrodes combined with infusion of saline into the tissue may improve results. Our aim was to determine the efficacy of a previously optimized hybrid ICE system (ICE combined with infusion of saline into the tissue at a distance of 2 mm) in comparison with a conventional ICE cluster electrode in porcine liver in vivo.MethodsA total of 32 RFA were performed on a total of 10 farm pigs using two RFA systems: Group A (n = 16): Cluster electrode. Group B (n = 16): Hybrid system (with continuous infusion of 100 ml/h of 20% NaCl at 2 mm distance from the electrode shaft by an independent isolated needle). Livers were removed for macroscopic and histological assessment after the procedure. Coagulation volume, coagulation diameters, coefficient of variability (CV) of coagulation volume, sphericity ratio (SR), deposited power (DP), deposited energy (DE), deposited energy per coagulation volume (DEV) and rise of animal temperature during the procedure were compared and correlated among groups. Additionally, linear regression analysis was modeled to study the relationship between deposited energy and either coagulation volume and rise of animal temperature during the procedure in both groups.ResultsBoth coagulation volume and short diameter of coagulation were significantly greater (p < 0.05) in group B compared to group A (22.7 ± 11.0 cm3 and 3.1 ± 0.7 cm vs. 13.5 ± 7.7 cm3 and 2.5 ± 0.5 cm, respectively). A similar CV and SR was observed among groups (57.1% and 1.4 ± 0.3 vs. 48.6% and 1.3 ± 0.2 for groups B and A, respectively). In group B, DE and DP were more than double group A, but DEV was nearly twice as high (9782 J/cm3 vs. 5342 J/cm3, for groups B and A, respectively). No significant relationship between DE and coagulation volume was encountered.ConclusionEfficacy of a single ICE may be improved with continuous infusion of saline at around 2 mm from the electrode shaft. Coagulation volume obtained with this improved system may be even greater than that obtained with a cluster electrode.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: European Journal of Surgical Oncology (EJSO) - Volume 34, Issue 7, July 2008, Pages 822–830
نویسندگان
, , , , , , , , , , , , ,