کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4047621 1603600 2007 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Observations on Bone Tunnel Enlargement After Double-Bundle Anterior Cruciate Ligament Reconstruction
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Observations on Bone Tunnel Enlargement After Double-Bundle Anterior Cruciate Ligament Reconstruction
چکیده انگلیسی

Purpose: The purpose of this study was to determine the amount of tibial and femoral bone tunnel enlargement after double-bundle anterior cruciate ligament (ACL) reconstruction. Methods: Twenty-five consecutive patients undergoing primary double-bundle hamstring ACL reconstruction were included in a prospective case series. Femoral fixation was performed by means of 2 EndoButton CL devices (Smith & Nephew Endoscopy, Andover, MA), and tibial fixation was done with 2 bioresorbable interference screws. Magnetic resonance imaging (MRI) was performed in all patients at a mean of 12.3 months postoperatively. Tunnel enlargement was determined by digitally measuring the widths perpendicular to the long axis of the anteromedial (AM) and posterolateral (PL) tunnels on an oblique coronal and axial plane. The MRI measurements were compared with the intraoperative drill diameter. Results: The mean tibial AM bone tunnel diameter increased from 0.74 to 1.06 cm, and the mean PL diameter increased from 0.60 to 0.89 cm. The mean femoral AM bone tunnel diameter increased from 0.71 to 0.97 cm, and the mean PL diameter increased from 0.58 to 0.85 cm. Bone tunnel enlargement was 43% (P = .001) for both tibial tunnels and 35% (P = .001) versus 48% (P < .001) for the femoral AM bone tunnel versus the PL femoral bone tunnel. On the tibial side, communication of the bone tunnels occurred in 41% of patients. Conclusions: This study shows significant tibial and femoral bone tunnel enlargement on MRI after 4-tunnel double-bundle ACL reconstruction 1 year postoperatively. In 41% of patients separate tibial bone tunnel measurements were impossible because of tunnel communication caused by intraoperative bone tunnel drilling, screw contact, or postoperative bone tunnel enlargement. On the femoral side, no bone tunnel communication occurred. The short-term clinical results were good and were not influenced by tunnel communication. Level of Evidence: Level IV, therapeutic case series.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Arthroscopy: The Journal of Arthroscopic & Related Surgery - Volume 23, Issue 3, March 2007, Pages 291–298
نویسندگان
,