کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4050579 1264944 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Biomechanical analysis of a synthetic femur spiral fracture model: Influence of different materials on the stiffness in flexible intramedullary nailing
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Biomechanical analysis of a synthetic femur spiral fracture model: Influence of different materials on the stiffness in flexible intramedullary nailing
چکیده انگلیسی

BackgroundFlexible intramedullary nail fixation of dislocated diaphyseal femur fractures has gained wide acceptance for children and adolescents with open physes. Studies with a special emphasis on complications reveal frequent problems regarding stability, usually in complex fracture types such as spiral fractures and in older children weighing > 40 kg. This biomechanical study analyses how much the material of the nails influences the stiffness in a synthetic bone model.MethodsTwenty-four composite grafts (Sawbones®, 4th generation, medullar canal of 10 mm) with an identical spiral fracture were used in three configurations of eight grafts. Elastic stable intramedullary nailing was performed in a retrograde C-shaped manner with two nails of equal size (2 × 3.5 mm). Close contact of the fragments could be achieved. We compared Group A (steel nails) with Group B and C (two types of titanium nails). All specimens underwent 4-point bending, torsion and axial compression in the 0° and 9° positions, and the results were analysed.FindingsGroup A (steel nails) revealed a significantly higher stiffness in all directions than Group B. Apart from compression in the 9° position this steel nail fixation showed significant higher stiffness than titanium nails of Group C. Comparing Group B and C did not show an systematic difference.InterpretationIn this biomechanical study with composite artificial bones the use of steel Nails demonstrated the highest stiffness in our model when compared to two different titanium nail configurations. Apart from in cases of known allergy or planned MRI-examinations our results and data from the literature question the use of titanium nails.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Biomechanics - Volume 26, Issue 6, July 2011, Pages 592–597
نویسندگان
, , , , , , , , ,