Biomechanical Differences Exhibited During Sit-To-Stand Between Total Knee Arthroplasty Designs of Varying Radii
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Biomechanical Differences Exhibited During Sit-To-Stand Between Total Knee Arthroplasty Designs of Varying Radii
چکیده انگلیسی

The purpose of the study was to investigate the influence of the mechanical differences between a single-radius total knee arthroplasty (SR TKA) and a multi-radius (MR) TKA design on the functional performance during a sit-to-stand movement. Three-dimensional kinematics and electromyography for selected knee flexor and extensor muscles were obtained for 16 (8 SR and 8 MR) unilateral, posterior-stabilized TKA participants. Compared to the SR group, the MR group demonstrated compensatory adaptations, with increases in performance time, trunk flexion displacement and velocity, and knee extensor electromyography; and greater relative hamstring co-activation of the MR limbs was needed to increase joint stability. An initial knee abduction displacement was exhibited by more MR than SR participants. In conclusion, SR TKA provides functional benefits to patients.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Arthroplasty - Volume 21, Issue 8, December 2006, Pages 1193–1199