کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4269733 1610850 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Penile Doppler Ultrasound in Men with Stuttering Priapism and Sickle Cell Disease—A Labile Baseline Diastolic Velocity Is a Characteristic Finding
ترجمه فارسی عنوان
سونوگرافی داپلر آلت تناسلی در مردان مبتلا به پرایاپیسم و ​​بیماری سلول های سکته مغزی یک روش تشخیص سریع تشخیص دیاستولیک
کلمات کلیدی
لکنت پرایپیسم، بیماری سل سقط، داپلر آلت تناسلی، سونوگرافی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی اورولوژی
چکیده انگلیسی

IntroductionStuttering priapism (SP) is seen in sickle cell disease (SCD) and characterized by short‐lived painful erections. Imbalanced vascular tone is the postulated cause and this may be reflected in changes in baseline penile blood flow as measured using penile Doppler ultrasound (PDU).AimThe aim of this study was to investigate the baseline penile blood flow characteristics in men with SCD and SP, by comparing with men without SP.MethodsPDU findings were retrospectively analyzed in 100 men during flaccid state. Nine men had SP (age range 20–40 years), 4 had Peyronie's disease (PD) (35–48 years), 67 men had erectile dysfunction (16–67 years), and 20 men had normal erectile function (18–42 years).Main Outcome MeasuresThe variables measured were peak systolic and end‐diastolic velocities, and the Doppler velocity waveform. Values in men with SP were compared with those in the other groups.ResultsMedian systolic and diastolic velocity was significantly higher in men with SP (systolic/diastolic velocity was 26/4 cm/second in men with SP vs. 13/0 cm/second, 14/0 cm/second, and 16/0 cm/second in men with PD, ED, and normal erectile function, respectively; P = 0.0001). Men with SP had a characteristic low peripheral resistance (PR) waveform with fluctuating velocities; the diastolic velocity was consistently positive (2–7 cm/second) and fluctuated between +2 and +8 cm/second. In comparison, the other 91 men had high PR waveform and consistently negative diastolic velocity (range 0 to −2 cm/second).ConclusionsMen with SP had a unique baseline Doppler ultrasound waveform, with a low PR waveform and an elevated, variable cavernosal artery velocity. We propose that this may be the sonographic manifestation of a reduced, fluctuating smooth muscle tone and that PDU may have a role for diagnosis and therapeutic monitoring of SP. Patel U, Sujenthiran A, and Watkin N. Penile Doppler ultrasound in men with stuttering priapism and sickle cell disease—A labile baseline diastolic velocity is a characteristic finding. J Sex Med 2015;12:549–556.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Sexual Medicine - Volume 12, Issue 2, February 2015, Pages 549–556
نویسندگان
, , ,