کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4299927 1288405 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Randomized clinical study evaluating the impact of mesh pore size on chronic pain after Lichtenstein hernioplasty
ترجمه فارسی عنوان
مطالعه بالینی تصادفی شده با هدف بررسی تأثیر اندازه عروق مش بر درد مزمن پس از لیزر لیپوپلاستی لیختن اشتاین
کلمات کلیدی
فتق القایی، فتق لیختن اشتاین، اندازه منفذ، درد مزمن، احساس عضو خارجی، کیفیت زندگی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
چکیده انگلیسی

BackgroundThe primary aim of this study was to determine whether mesh pore size influences the rate of chronic pain at 6-mo follow-up. Another aim was to evaluate the rate of foreign body feeling and quality of life after inguinal hernia repair.MethodsThe patients were randomized into two study groups: the UM group received Ultrapro mesh (pore size 3–4 mm) and the OM group received Optilene LP mesh (pore size 1 mm). Pain scores were measured on a visual analog scale. The feeling of a foreign body was a yes-or-no question. Quality of life was evaluated using the Medical Outcome Study Short-Form-36 questionnaire.ResultsA total of 67 patients in the UM group and 67 patients in the OM group were investigated 6 mo after operation. There were no significant differences in the results of the pain questionnaire between the study groups. Of the patients, 46.3% in the UM group reported pain during different activities at 6-mo follow-up versus 34.3% in the OM group (P = 0.165). The feeling of a foreign body in the inguinal region was experienced by 47.8% of the patients in the UM group and by 31.3% of the patients in the OM group at 6-mo follow-up (P = 0.052; risk ratio 1.52, 95% confidence interval: 1.00–2.37). There were no significant differences in the quality of life according to the Short-Form 36 questionnaire between the two study groups at 6-mo follow-up. In both study groups, the quality of life scores improved after operation by most dimensions.ConclusionsDifferences in mesh pore size did not influence the rate of chronic pain. Although there was a trend for higher rate of foreign body feeling in the study group where a mesh with larger pores was used, we failed to find an explanation for this. The pore size of meshes investigated in this study did not affect the quality of life after inguinal hernia repair. Considering the fact that the quality of life improved significantly after operation, elective repair of symptomatic inguinal hernias should be undertaken as promptly as possible.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Surgical Research - Volume 191, Issue 2, October 2014, Pages 311–317
نویسندگان
, , , , , ,