کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4409424 1307482 2013 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of the gas stripping technique for calculation of Henry’s law constants using the initial slope method for 1,2,4,5-tetrachlorobenzene, pentachlorobenzene, and hexachlorobenzene
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست شیمی زیست محیطی
پیش نمایش صفحه اول مقاله
Evaluation of the gas stripping technique for calculation of Henry’s law constants using the initial slope method for 1,2,4,5-tetrachlorobenzene, pentachlorobenzene, and hexachlorobenzene
چکیده انگلیسی

Henry’s law constant (HLC) is an important factor used in environmental risk assessment and fate and transport models to describe mass transfer of chemical between water and air. HLCs and structure–property relationships were assessed for 1,2,4,5-tetrachlorobenzene (TeCB), pentachlorobenzene (PeCB), and hexachlorobenzene (HCB). HLCs were determined using the volatilization rate (kv) of sparged chemical at 25 °C. Despite the assumption that kv should be constant throughout the stripping duration, results indicated that kv decreased over time according to three separate slope regions. Results of ANCOVA indicate that kv is statistically different in the third slope region, which leads to the conclusion that use of the entire stripping data set would lead to biased HLCs. This decrease in kv may be attributed to desorption from sparger surfaces, which has not been considered widely in the literature. Statistical analysis was possible because of the robustness of the current experimental procedure which included numerous replications (15 total spargers) and extensive data points available to discern key slope changes. HLCs determined using the gas stripping technique were 57, 33, and 30 Pa m3 mol−1 for 1,2,4,5-TeCB, PeCB, and HCB, respectively. In comparison to literature values, current TeCB and HCB HLCs were within wide reference ranges spanning approximately an order of magnitude for each chemical. PeCB HLC of the current study was two times lower than the lowest reference data.


► Henry’s law constant (HLC) reference uncertainty is high.
► HLCs assessed for 3 chlorobenzenes via gas stripping.
► Volatilization rates decreased over time according to three slope regions.
► Use of entire stripping data set leads to biased HLCs.
► Chlorobenzene HLCs differed from wide reference ranges.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemosphere - Volume 91, Issue 11, June 2013, Pages 1648–1652
نویسندگان
, , ,