کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4411170 1307581 2011 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Emissions of PCDD and PCDF from combustion of forest fuels and sugarcane: A comparison between field measurements and simulations in a laboratory burn facility
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست شیمی زیست محیطی
پیش نمایش صفحه اول مقاله
Emissions of PCDD and PCDF from combustion of forest fuels and sugarcane: A comparison between field measurements and simulations in a laboratory burn facility
چکیده انگلیسی

Release of PCDD and PCDF from biomass combustion such as forest and agricultural crop fires has been nominated as an important source for these chemicals despite minimal characterisation. Available emission factors that have been experimentally determined in laboratory and field experiments vary by several orders of magnitude from <0.5 μg TEQ (t fuel consumed)−1 to >100 μg TEQ (t fuel consumed)−1. The aim of this study was to evaluate the effect of experimental methods on the emission factor.A portable field sampler was used to measure PCDD/PCDF emissions from forest fires and the same fuel when burnt over a brick hearth to eliminate potential soil effects. A laboratory burn facility was used to sample emissions from the same fuels. There was very good agreement in emission factors to air (EFAir) for forest fuel (Duke Forest, NC) of 0.52 (range: 0.40–0.79), 0.59 (range: 0.18–1.2) and 0.75 (range: 0.27–1.2) μg TEQWHO2005 (t fuel consumed)−1 for the in-field, over a brick hearth, and burn facility experiments, respectively. Similarly, experiments with sugarcane showed very good agreement with EFAir of 1.1 (range: 0.40–2.2), 1.5 (range: 0.84–2.2) and 1.7 (range: 0.34–4.4) μg TEQ (t fuel consumed)−1 for in-field, over a brick hearth, open field and burn facility experiments respectively. Field sampling and laboratory simulations were in good agreement, and no significant changes in emissions of PCDD/PCDF could be attributed to fuel storage and transport to laboratory test facilities.


► A portable field sampler used to measure PCDD/PCDF emissions from forest fuels.
► Same fuel burnt over a brick hearth to eliminate potential soil effects.
► Laboratory burn facility used to sample emissions from the same fuels.
► Field sampling and laboratory simulations were in good agreement.
► No significant changes in PCDD/PCDF EFs attributed to fuel storage/transport.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemosphere - Volume 83, Issue 10, May 2011, Pages 1331–1338
نویسندگان
, , , , , ,