کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4415679 | 1307755 | 2007 | 8 صفحه PDF | دانلود رایگان |

A thermal degradation procedure for reducing the concentrations of mono- to octa-chlorinated PCDD/Fs, PCBs and hexa-chlorobenzenes (HCB) in filter ash from incinerated municipal solid waste (MSW) is described. Thermal treatment of filter ash samples at 500 °C for 60 min in a closed system providing low oxygen conditions resulted in 97% and 99% reductions in the total and I-TEQ concentrations of PCDD/Fs, to 6.8 μg kg−1 ash and <0.05 μg I-TEQ kg−1 ash, respectively. Increasing the thermal treatment time to 480 min, at the same temperature, yielded 99% reductions in both total and I-TEQ concentrations of the mono- to octa-chlorinated PCDD/Fs. Similar effects were observed for HCB and PCBs. The data from this study indicate that PCDD/Fs and other toxic organic compounds in ash from incinerated MSW, can be effectively degraded by this procedure, which combines relatively low-temperatures, short treatment times, and low oxygen conditions.
Journal: Chemosphere - Volume 67, Issue 3, March 2007, Pages 474–481