کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4471802 | 1315044 | 2012 | 7 صفحه PDF | دانلود رایگان |

The input and output samples from existing large-scale municipal solid waste incinerator (MSWI) were collected and analyzed for polychlorinated dibenzo-р-dioxins and dibenzofurans (PCDD/Fs) in this study, aiming to evaluate PCDD/F characteristic and the corresponding mass balance through the whole system. The grate-type MSWI is equipped with semi-dry scrubber, activated carbon injection, and bag filter as air pollutant control devices (APCDs). Results showed that on the output side, the stack gas, bottom ash and fly ash presented their mean dioxin levels of 0.078 ng I-TEQ/Nm3, 12.94 ng I-TEQ/kg and 858 ng I-TEQ/kg, respectively, and showed large similarities in congener profiles. Instead, on the input side, the municipal solid waste (MSW) presented a mean dioxin level of 15.56 ng I-TEQ/kg and a remarkable difference in congener profiles compared with those of the output. The dioxin mass balance demonstrated that the annual dioxin input value was around 5.38 g I-TEQ/yr, lower than the total output value (7.62 g I-TEQ/yr), signifying a positive dioxin balance of about 2.25 g I-TEQ/yr.
► The dioxin contents were presented in input and output samples from a MSWI.
► The congener profiles of dioxin were compared from input and output samples.
► An accurate dioxin mass balance was performed.
Journal: Waste Management - Volume 32, Issue 6, June 2012, Pages 1156–1162