Liquid chromatography-tandem mass spectrometry method for the determination of thiosulfate in human blood and urine as an indicator of hydrogen sulfide poisoning
ترجمه فارسی عنوان
روش اسپکترومتری جرمی کروماتوگرافی مایع دو بعدی برای تعیین تیزوالفات در خون و ادرار انسان به عنوان شاخصی از مسمومیت با سولفید هیدروژن
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


- Quantitative determination method for thiosulfate by LC-MS/MS was developed.
- Thiosulfate can be utilized for an index of hydrogen sulfide poisoning.
- The established method is more rapid and simple comparing to GC/MS method.
- The method could estimate thiosulfate concentrations in 12 forensic autopsy cases.

Being a stable metabolite of hydrogen sulfide, thiosulfate has been utilized as an index for hydrogen sulfide poisoning (HSP). Thiosulfate analysis is mainly performed using gas chromatography/mass spectrometry (GC-MS) due to its high sensitivity and specificity. The GC-MS analysis requires two-step derivatizations of thiosulfate, and the derivative is not stable in solution as it has a disulfide moiety. To resolve this stability issue, we developed a novel analytical method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for monitoring the pentafluorobenzyl derivative of thiosulfate (the first reaction product of the GC-MS method) in this study. The established method exhibited high reproducibility despite being a more simplified and rapid procedure compare to the GC-MS method. Phenyl 4-hydroxybenzoate was used as an internal standard because 1,3,5-tribromobenzene which had been used in the GC-MS method was not suitable compound for LC-MS/MS with Electrospray ionization (ESI) negative detection. The linear regression of the peak area ratios versus concentrations was fitted over the concentration ranges of 0.5-250 μM and 0.25-250 μM in blood and urine, respectively. The validation results satisfied the acceptance criteria for intra- and inter-day accuracy and precision. Blood and urine samples from 12 suspected HSP cases were tested using this method. The thiosulfate concentration detected in the sample coincided well with that determined at the scene of each HSP accident.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Legal Medicine - Volume 24, January 2017, Pages 67-74
نویسندگان
, , , , , , , , , , , ,