CCGTGBRERRLCCAEPSCEIRMSEGHGASHRAEtWHInternational Performance Measurement and Verification ProtocolEPBDEUIGWHU-value - ارزش Unet present value - ارزش خالص فعلیUnited Arab Emirates - امارات متحده عربیUAE - امارات متحده عربیRetrofit - بازسازیEnergy efficiency - بهره وری انرژیLife cycle cost analysis - تجزیه و تحلیل هزینه چرخه زندگیHVAC - تهویه مطبوعCombined cycle gas turbine - توربین گاز چرخه ترکیبیError - خطاDry bulb temperature - دمای لامپ خشکRelative humidity - رطوبت نسبیroot mean squared error - ریشه متوسط خطای مربعcoefficients of variation - ضرایب تنوعXPS - طیف نگاری فوتوالکترونی اشعه ایکسInsulation - عایقNPV یا negative predictive value - مقادیر پیش بینی شده منفیmillion tons - میلیون تنExpanded polystyrene - پلی استایرنExtruded polystyrene - پلی استایرن اکسترود شدهGreenhouse gas - گاز گلخانه ایheating, ventilation, and air conditioning - گرمایش، تهویه و تهویه مطبوعGigawatt hour - یک گیگاوات ساعت
موضوعات مرتبط
مهندسی و علوم پایه
سایر رشته های مهندسی
مهندسی عمران و سازه
چکیده انگلیسی
The rapid economic growth of Dubai over the past three decades has triggered the construction of a large number of residential villas. Most of these were built before the first energy efficiency regulation came into effect in 2003 and, while new energy efficiency regulations are applied in buildings of new construction, the existing building stock remains energetically inefficient. The viability of different retrofit measures is examined here using two calibrated energy models of villas typical of different urban development periods. The retrofit measures considered focus on both envelope and air conditioning system, with energy targets selected at two efficiency levels: first, the level required by the current Dubai Green Building Regulations, and second, required efficiency levels to the stricter demands of the German Building Regulation. Results indicate that improving wall insulation to a U value of 0.3Â W/m2Â K, and upgrading the Air Conditioning system to a COP of 2.78, is financially viable and has a significant effect on energy consumption and CO2 equivalent emissions. Considering the existing building stock, the effect of applying these measures at an Emirate-wide scale can reduce summer peak demand by 40% and CO2 emissions for the villas by nearly 32%.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Building Engineering - Volume 13, September 2017, Pages 116-126
Journal: Journal of Building Engineering - Volume 13, September 2017, Pages 116-126
نویسندگان
Kambiz Rakhshan, Wilhelm A. Friess,