کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4990763 1457102 2017 34 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Performance of a 5 kW hot water driven diffusion absorption chiller
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Performance of a 5 kW hot water driven diffusion absorption chiller
چکیده انگلیسی
This paper presents experimental results of a 5 kW Diffusion-Absorption Chiller (DAC). The chiller has been tested at varying inlet generator temperatures, inlet cooling water temperatures and inlet chilled water temperatures. The lowest driving temperature to keep the bubble pump running was about 90 °C with 3.6 kW cooling capacity and chilled water inlet temperature being set at 18 °C. The maximum cooling capacity and COP reached for the DAC was about 4.52 kW and 0.45, respectively. The prototype has demonstrated a good potential for air-conditioning applications, while not requiring electricity internally for its operation and allowing coupling with waste heat or solar thermal collector systems.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 127, 25 December 2017, Pages 789-799
نویسندگان
, , , , ,