کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5031630 1470940 2017 15 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Detection of the tau protein in human serum by a sensitive four-electrode electrochemical biosensor
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Detection of the tau protein in human serum by a sensitive four-electrode electrochemical biosensor
چکیده انگلیسی
This study presents a novel approach based on a four-electrode electrochemical biosensor for the detection of tau protein - one of the possible markers for the prediction of Alzheimer's disease (AD). The biosensor is based on the formation of stable antibody-antigen complexes on gold microband electrodes covered with a layer of a self-assembled monolayer and protein G. Antibodies were immobilized on the gold electrode surface in an optimal orientation by protein G interaction. Electrochemical impedance spectroscopy was used to analyze impedance change, which revealed a linear response with increasing tau concentrations. The assay is fast (<1 h for incubation and measurement) and very sensitive. The limit of quantification for the full-length 2N4R tau protein is 0.03 pM, a value unaltered when the assay was processed in bovine serum albumin or human serum. This technology could be adapted for the detection of other biomarkers to provide a multiple assay to identify AD progression in a point of care setting.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 92, 15 June 2017, Pages 482-488
نویسندگان
, , , , , , ,