Controlled, synchronized actuation of microdroplets by gravity in a superhydrophobic, 3D-printed device
چکیده انگلیسی


- A 3D-printed device was coated with a superhydrophobic spray and placed in a holder.
- Controlled actuation of 10-50 μL droplets was possible by gravity alone.
- The superhydrophobic coating allowed actuation of various biological fluids.
- Using an integrated microelectrode, glucose in droplets of rat serum was measured.
- The device is readily customizable for other applications.

Droplet manipulation over open surfaces allows one to perform assays with a large degree of control and high throughput, making them appealing for applications in drug screening or (bio)analysis. However, the design, manufacturing and operation of these systems comes with high technical requirements. In this study we employ a commercial, low-friction, superhydrophobic coating, Ultra-Ever Dry®, on a 3D-printed microfluidic device. The device features individual droplet compartments, which allow the manipulation of discrete droplets (10-50 μL) actuated by gravity alone. Simply by angling the device to normal in a 3D-printed holder and rocking in a “to and fro”-fashion, a sequence of droplets can be individually transferred to an electrochemical microelectrode detector and then to waste, while preserving the (chronological) order of samples. Multiple biological fluids (i.e. human saliva, urine and rat blood and serum) were successfully tested for compatibility with the device and actuation mechanism, demonstrating low slip angles and high contact angles. Biological matrix (protein) carryover was probed and effectively mitigated by incorporating aqueous rinse droplets as part of the analysis sequence. As a proof-of-concept, the enzyme-coupled, amperometric detection of glucose was carried out on individual rat serum droplets, enabling total analysis in ≈30 min, including calibration. The device is readily customizable, and the integration of droplet generation techniques and other sensor systems for different analytes of interest or applications can be realized in a plug and play fashion.

379

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 988, 2 October 2017, Pages 50-57
نویسندگان
, , , ,