کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5130972 1490858 2017 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Paper-based microfluidic devices on the crime scene: A simple tool for rapid estimation of post-mortem interval using vitreous humour
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Paper-based microfluidic devices on the crime scene: A simple tool for rapid estimation of post-mortem interval using vitreous humour
چکیده انگلیسی


- Paper-based devices were proposed to estimate the post-mortem interval using vitreous humor as biological fluid.
- Wax printing technology was used to fabricate a 60-microzone array and a Y-shaped device.
- Digital image analysis provided high specificity, reliability and accuracy.
- The data achieved with paper devices did not differ from those found by ICP-MS at a confidence level of 95%.

This paper describes for the first time the use of paper-based analytical devices at crime scenes to estimate the post-mortem interval (PMI), based on the colorimetric determination of Fe2+ in vitreous humour (VH) samples. Experimental parameters such as the paper substrate, the microzone diameter, the sample volume and the 1,10-phenanthroline (o-phen) concentration were optimised in order to ensure the best analytical performance. Grade 1 CHR paper, microzone with diameter of 5 mm, a sample volume of 4 μL and an o-phen concentration of 0.05 mol/L were chosen as the optimum experimental conditions. A good linear response was observed for a concentration range of Fe2+ between 2 and 10 mg/L and the calculated values for the limit of detection (LOD) and limit of quantification (LOQ) were 0.3 and 0.9 mg/L, respectively. The specificity of the Fe2+ colorimetric response was tested in the presence of the main interfering agents and no significant differences were found. After selecting the ideal experimental conditions, four HV samples were investigated on paper-based devices. The concentration levels of Fe2+ achieved for samples #1, #2, #3 and #4 were 0.5 ± 0.1, 0.7 ± 0.1, 1.2 ± 0.1 and 15.1 ± 0.1 mg/L, respectively. These values are in good agreement with those calculated by ICP-MS. It important to note that the concentration levels measured using both techniques are proportional to the PMI. The limitation of the proposed analytical device is that it is restricted to a PMI greater than 1 day. The capability of providing an immediate answer about the PMI on the crime scene without any sophisticated instrumentation is a great achievement in modern instrumentation for forensic chemistry. The strategy proposed in this study could be helpful in many criminal investigations.

245

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 974, 29 June 2017, Pages 69-74
نویسندگان
, , , , , , , , ,