کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5133228 | 1492062 | 2017 | 7 صفحه PDF | دانلود رایگان |
- Rapid and sensitive HPLC-APCI-MS/MS method for COPs analysis in milk powder based foods.
- Direct saponification of sample and purification of oxysterols by reversed phase C18 SPE.
- The oxysterols extraction and enrichment are combined in one step.
- The method reduces the sample manipulation and possible artifacts formation.
A rapid and sensitive HPLC-APCI-MS/MS method for the determination of cholesterol oxidation products (COPs) in milk powder based foods is reported. The method consists in the direct saponification of the sample and purification of oxysterols by reversed phase C18-SPE followed by HPLC-MS/MS analysis. By this procedure, the extraction and enrichment of oxysterols are combined in a unique step, reducing sample manipulation and the possible formation of artifacts. LOD and LOQ were in the concentration ranges of 2-8 ng gâ1 and 8-30 ng gâ1, respectively. The precision (CV%) was in the range 10-36% in fresh samples with a total COPs amount from 212 to 645 ng gâ1 and 6-14% for an oxidized sample with a higher amount (3651 ng gâ1). The recovery ranged from 74 ± 8% for 7-ketocholesterol to 101 ± 12% for 7α-hydroxycholesterol at 200 ng gâ1 and from 82 ± 2% for 7-ketocholesterol to 117 ± 10% for 5α,6α-epoxycholesterol at 500 ng gâ1 spiked levels, respectively.
Journal: Food Chemistry - Volume 230, 1 September 2017, Pages 604-610