کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5135344 1493421 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Validated high-performance anion-exchange chromatography with pulsed amperometric detection method for the determination of residual keratan sulfate and other glucosamine impurities in sodium chondroitin sulfate
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Validated high-performance anion-exchange chromatography with pulsed amperometric detection method for the determination of residual keratan sulfate and other glucosamine impurities in sodium chondroitin sulfate
چکیده انگلیسی


- A new HPAEC-PAD method for the quantitation of the residual KS in CS was validated.
- It was more specific than the electrophoretic one reported in CS monograph (USP/EP).
- Quantitation of KS in marine and terrestrial CS was quite different.
- Residual KS was found even in terrestrial and marine USP and EP reference standard.
- Update of the CS monograph is needed to have a more specific method for impurities.

An efficient and sensitive analytical method based on high-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) was devised for the determination of glucosamine (GlcN) in sodium chondroitin sulfate (CS). Glucosamine (GlcN) is intended as marker of residual keratan sulfate (KS) and other impurities generating glucosamine by acidic hydrolyzation. The latter brings CS and KS to their respective monomers. Since GlcN is present only in KS we developed a method that separates GlcN from GalN, the principal hydrolytic product of CS, and then we validated it in order to quantify GlcN. Method validation was performed by spiking CS raw material with known amounts of KS. Detection limit was 0.5% of KS in CS (corresponding to 0.1 μg/ml), and the linear range was 0.5-5% of KS in CS (corresponding to 0.1-1 μg/ml). The optimized analysis was carried out on an ICS-5000 system (Dionex, Sunnyvale, CA, USA) equipped with a Dionex Amino Trap guard column (3 mm × 30 mm), Dionex CarboPac-PA20 (3 mm × 30 mm) and a Dionex CarboPac-PA20 analytical column (3 mm × 150 mm) using gradient elution at a 0.5 ml/min flow rate. Regression equations revealed good linear relationship (R2 = 0.99, n = 5) within the test ranges. Quality parameters, including precision and accuracy, were fully validated and found to be satisfactory. The fully validated HPAEC-PAD method was readily applied for the quantification of residual KS in CS in several raw materials and USP/EP reference substance. Results confirmed that the HPAEC-PAD method is more specific than the electrophoretic method for related substance reported in EP and provides sensitive determination of KS in acid-hydrolyzed CS samples, enabling the quantitation of KS and other impurities (generating glucosamine) in CS.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1505, 7 July 2017, Pages 43-49
نویسندگان
, , , , , ,