کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5135536 1493429 2017 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Solid-phase microextraction set-up for the analysis of liver volatolome to detect livestock exposure to micropollutants
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Solid-phase microextraction set-up for the analysis of liver volatolome to detect livestock exposure to micropollutants
چکیده انگلیسی


- An SPME protocol for liver volatolomics was set up.
- Key factors were temperature, sample defrosting time and salt addition.
- Representativity, recovery, variability of volatolome extraction were improved.
- The protocol enabled to detect VOC markers of chicken exposure to 3 contaminants.

Starting from a critical analysis of a first “proof of concept” study on the utility of the liver volatolome for detecting livestock exposure to environmental micropollutants (Berge et al., 2011), the primary aim of this paper is to improve extraction conditions so as to obtain more representative extracts by using an extraction temperature closer to livestock physiological conditions while minimizing analytical variability and maximizing Volatile Organic Compound (VOC) abundancies. Levers related to extraction conditions and sample preparation were assessed in the light of both abundance and coefficient of variation of 22 candidate VOC markers identified in earlier volatolomic studies. Starting with a CAR/PDMS fiber and a 30 min extraction, the reduction of SPME temperature to 40 °C resulted in a significant decrease in the area of 14 candidate VOC markers (p < 0.05), mainly carbonyls and alcohols but also a reduction in the coefficient of variation for 17 of them. In order to restore VOC abundances and to minimize variability, two approaches dealing with sample preparation were investigated. By increasing sample defrosting time at 4 °C from 0 to 24 h yielded higher abundances and lower variabilities for 15 and 13 compounds, respectively. Lastly, by using additives favouring the release of VOCs (1.2 g of NaCl) the sensitivity of the analysis was improved with a significant increase in VOC abundances of more than 50% for 13 out of the 22 candidate markers. The modified SPME parameters significantly enhanced the abundances while decreasing the analytical variability for most candidate VOC markers. The second step was to validate the ability of the revised SPME protocol to discriminate intentionally contaminated broiler chickens from controls, under case/control animal testing conditions. After verification of the contamination levels of the animals by national reference laboratories, data analysis by a multivariate chemometric method (Common Components and Specific Weights Analysis − ComDim) showed that the liver volatolome could reveal dietary exposure of broilers to a group of environmental pollutants (PCBs), a veterinary treatment (monensin), and a pesticide (deltamethrin), thus confirming the usefulness of this analytical set-up.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1497, 12 May 2017, Pages 9-18
نویسندگان
, , , , , , , , , , , , ,