- BSTFA interfered with the trimethylsilyl derivatives of short-chain alcohols.
- Interference of BSTFA was eliminated by a base treatment.
- Trimethylsilyl derivatives were found intact with the base treatment.
- Method was validated successfully for analytes at level of parts per billion.
- This novel base treatment strategy broadened the BSTFA applicability.
A novel base treatment followed by liquid-liquid extraction was developed to remove the interference of excess derivatization reagent BSTFA [N,O-Bis(trimethylsilyl)trifluoroacetamide] and its byproducts for trace determination of 1-chloro-2-propanol and 2-chloro-1-propanol in a food additive. The corresponding trimethylsilyl derivatives were analyzed by gas chromatography mass spectrometry (GC/MS) detection in selective ion monitoring mode. Due to a large volume splitless injection needed for achieving the required sensitivity, excess BSTFA in the derivatization sample solution interfered with the trimethylsilyl derivatives of the analytes of interest, making their quantitation not attainable. Efforts were made to decompose BSTFA while keeping the trimethylsilyl derivatives intact. Water or aqueous sulfuric acid treatment converted BSTFA into mainly N-trimethylsilyltrifluoroacetamide, which partitions between aqueous and organic layers. In contrast, aqueous sodium hydroxide decomposed BSTFA into trifluoroacetic acid, which went entirely into the aqueous layer. No BSTFA or its byproduct N-trimethylsilyltrifluoroacetamide or trifluroacetamide was found in the organic layer where the derivatized alcohols existed, which in turn completely eliminated their interference, enabling accurate and precise determination of parts per billion of the short-chain alcohols in the food additive. Contrary to the conventional wisdom that a trimethylsilyl derivative is susceptible to hydrolysis, the derivatized short-chain alcohols were found stable even in the presence of 0.17Â N aqueous sodium hydroxide as the improved GC/MS method was validated successfully, with a satisfactory linearity response in the concentration range of 10-400Â ng/g (regression coefficient greater than 0.999), good method precision (<4%), good recovery (90-98%), and excellent limit of detection (3Â ng/g) and limit of quantitation (10Â ng/g).
Journal: Journal of Chromatography A - Volume 1490, 24 March 2017, Pages 74-79