کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5136052 1493457 2016 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Intelligent peak deconvolution through in-depth study of the data matrix from liquid chromatography coupled with a photo-diode array detector applied to pharmaceutical analysis
ترجمه فارسی عنوان
تجزیه و تحلیل قله هوشمند در طی مطالعه عمیق ماتریس داده از کروماتوگرافی مایع همراه با یک آشکارساز آرایه ای عکس دیود اعمال شده به تجزیه و تحلیل دارویی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


- New algorithm to separate co-eluting peaks in data from HPLC-PDA was developed.
- This provides fast and robust analysis even when method developments efforts fail to achieve complete separation of target peaks.
- This approach is potentially applicable to co-eluted compounds having exactly the same molecular weight.
- This is complementary to the use of LC-MS to perform quantitative analysis on co-eluted compounds.

Multivariate curve resolution-alternating least squares (MCR-ALS) method was investigated for its potential to accelerate pharmaceutical research and development. The fast and efficient separation of complex mixtures consisting of multiple components, including impurities as well as major drug substances, remains a challenging application for liquid chromatography in the field of pharmaceutical analysis. In this paper we suggest an integrated analysis algorithm functioning on a matrix of data generated from HPLC coupled with photo-diode array detector (HPLC-PDA) and consisting of the mathematical program for the developed multivariate curve resolution method using an expectation maximization (EM) algorithm with a bidirectional exponentially modified Gaussian (BEMG) model function as a constraint for chromatograms and numerous PDA spectra aligned with time axis. The algorithm provided less than ±1.0% error between true and separated peak area values at resolution (Rs) of 0.6 using simulation data for a three-component mixture with an elution order of a/b/c with similarity (a/b) = 0.8410, (b/c) = 0.9123 and (a/c) = 0.9809 of spectra at peak apex. This software concept provides fast and robust separation analysis even when method development efforts fail to achieve complete separation of the target peaks. Additionally, this approach is potentially applicable to peak deconvolution, allowing quantitative analysis of co-eluted compounds having exactly the same molecular weight. This is complementary to the use of LC-MS to perform quantitative analysis on co-eluted compounds using selected ions to differentiate the proportion of response attributable to each compound.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1469, 21 October 2016, Pages 35-47
نویسندگان
, , , , , , ,