کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5206911 1382326 2010 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Test MethodInvestigation of curing behaviour of melamine/phenolic (MP) thermosets
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آلی
پیش نمایش صفحه اول مقاله
Test MethodInvestigation of curing behaviour of melamine/phenolic (MP) thermosets
چکیده انگلیسی

Commercially available melamine/phenolic (MP) moulding compounds used for manufacturing electro installation parts were investigated by laboratory thermal analysis methods: Dynamic Mechanical Analysis (DMA), Differential Scanning Calorimetry (DSC) and Dielectric Analysis (DEA). The results were compared with on-line measurements in a compression mould using incorporated dielectric and ultrasound sensors. Softening and cross-linking behaviour were analyzed. For on-line process monitoring, only the ultrasound method worked well. The dielectric method was distorted by water formed as a by-product from the poly-condensation reaction.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Polymer Testing - Volume 29, Issue 6, September 2010, Pages 723-728
نویسندگان
,