کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
5475719 | 1521415 | 2017 | 10 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
A new pH phenomenon to predict polarity reversal in lead-acid cells
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
انرژی (عمومی)
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
This paper discusses new experimental work investigating the change in pH of the electrolyte of individual cells in Lead-Acid batteries during discharge with a view to predicting cell polarity reversal and thereby pre-empting potentially catastrophic failure in batteries. The discharge tests were carried out on batteries which were classified as 'new' and 'aged' as a means of indicating their state of health. A new pH phenomenon has been recorded for the first time in this paper as evidenced by experimental results including measurement of half-cell potentials. The trends observed during the discharge tests could be used as additional means of indicating impending cell reversal in series connected lead-acid cells.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy - Volume 136, 1 October 2017, Pages 100-109
Journal: Energy - Volume 136, 1 October 2017, Pages 100-109
نویسندگان
J. Mooney, A. Alaswad, A. Cruden,