کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5485552 1399433 2017 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Ultrasound-Based Shear Wave Elastography in the Assessment of Patients with Diabetic Kidney Disease
ترجمه فارسی عنوان
الاستوگرافی موج برشی بر اساس اولتراسوند در ارزیابی بیماران مبتلا به بیماری کلیوی دیابتی
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم آکوستیک و فرا صوت
چکیده انگلیسی
In previous studies of acoustic radiation force impulse (ARFI) elastography, using Virtual Touch tissue quantification (VTQ) (Siemens Acuson S2000), it was reported that the measurement of renal shear wave speed in patients with chronic kidney disease (CKD) is not influenced exclusively by renal fibrosis. The purpose of the present study was to analyze the role of VTQ in patients with diabetic kidney disease, considered the main cause of CKD. The study group included 164 patients: 80 patients with diabetic kidney disease (DKD) and 84 without renal disease or diabetes mellitus. In each subject in lateral decubitus, five valid VTQ measurements were performed in each kidney and a median value was calculated, the result being expressed in meters/second. The following means of the median values were obtained In DKD patients, the means of the median values were for VTQ right kidney, 2.21 ± 0.71 m/s, and for VTQ left kidney, 2.13 ± 0.72 m/s, whereas in the normal controls statistically significant higher values were obtained: 2.58 ± 0.78 m/s for VTQ right kidney (p = 0.0017) and 2.46 ± 0.81 m/s for VTQ left kidney (p = 0.006). Patients with an estimated glomerular filtration rate (eGFR) >60 mL/min (DKD stages 1 and 2 together with normal controls) had a significantly higher kidney shear wave speed compared with patients with an eGFR <60 mL/min (2.53 m/s vs. 2.09 m/s, p < 0.05). In the DKD group, there was a significant correlation between eGFR and VTQ levels for the right kidney (r = 0.28, p = 0.04). There was no correlation of VTQ values with proteinuria level, stage of diabetic retinopathy or glycated hemoglobin. Our study indicates that shear wave speed values in patients with diabetic kidney disease and eGFRs <60 mL/min are significantly lower compared with those of patients with eGFRs >60 mL/min (either normal controls or diabetic patients with DKD stages 1 and 2), and values decrease with the decrease in eGFR. However, proteinuria, diabetic retinopathy and glycated hemoglobin have no influence on VTQ.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ultrasound in Medicine & Biology - Volume 43, Issue 10, October 2017, Pages 2159-2166
نویسندگان
, , , , , , , , , ,