کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5492486 1525684 2016 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The impact of SFCL and SMES integration on the distance relay
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم فیزیک ماده چگال
پیش نمایش صفحه اول مقاله
The impact of SFCL and SMES integration on the distance relay
چکیده انگلیسی
The superconducting fault current limiter (SFCL) is an ideal short-circuit fault current limiting device that can limit the fault current without any delay and control the voltage drop of the non-fault line. The superconducting magnetic energy storage (SMES) device can exchange the active and reactive power independently, so it is applied broadly to improve power system stability. With SFCL, the low voltage ride-through capability of SMES can be enhanced as well as its MW and MJ capacities. The distance relay is a key electrical apparatus that will trip circuit breakers to protect electrical devices from short circuit faults. Due to the application of SFCL and SMES integration, the voltage and current in power grid will change accordingly, and the operation characteristic of distance relay may be affected. In this paper, the impact of a bridge-type SFCL and SMES integration on the circle distance relay is studied. And simulation results show that the integration of SFCL and SMES does influence the measured impedance of distance relay, which can lead to mal-operation of the circle distance relay. Furthermore, an improved distance relay is proposed and verified.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Physica C: Superconductivity and its Applications - Volume 530, 15 November 2016, Pages 151-159
نویسندگان
, , , , ,