کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5558142 1561078 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Clinical outcome associated with the use of different inhalation method with and without humidification in asthmatic mechanically ventilated patients
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی ریوی و تنفسی
پیش نمایش صفحه اول مقاله
Clinical outcome associated with the use of different inhalation method with and without humidification in asthmatic mechanically ventilated patients
چکیده انگلیسی

BackgroundInhaled-medication delivered during mechanical-ventilation is affected by type of aerosol-generator and humidity-condition. Despite many in-vitro studies related to aerosol-delivery to mechanically-ventilated patients, little has been reported on clinical effects of these variables.The aim of this study was to determine effect of humidification and type of aerosol-generator on clinical status of mechanically ventilated asthmatics.Method72 (36 females) asthmatic subjects receiving invasive mechanical ventilation were enrolled and assigned randomly to 6 treatment groups of 12 (6 females) subjects each received, as possible, all inhaled medication using their assigned aerosol generator and humidity condition during delivery. Aerosol-generators were placed immediately after humidifier within inspiratory limb of mechanical ventilation circuit.First group used vibrating-mesh-nebulizer (Aerogen Solo; VMN) with humidification; Second used VMN without humidification; Third used metered-dose-inhaler with AeroChamber Vent (MDI-AV) with humidification; Forth used MDI-AV without humidification; Fifth used Oxycare jet-nebulizer (JN) with humidification; Sixth used JN without humidification.Measured parameters included clinical-parameters reflected patient response (CP) and endpoint parameters e.g. length-of-stay in the intensive-care-unit (ICU-days) and mechanical-ventilation days (MV-days).ResultsThere was no significant difference between studied subjects in the 6 groups in baseline of CP.VMN resulted in trend to shorter ICU-days (∼1.42days) compared to MDI-AV (p = 0.39) and relatively but not significantly shorter ICU-days (∼0.75days) compared JN. Aerosol-delivery with or without humidification did not have any significant effect on any of parameters studied with very light insignificant tendency of delivery at humid condition to decrease MV-days and ICU-days.No significant effect was found of changing humidity during aerosol-delivery to ventilated-patient.ConclusionsVMN to deliver aerosol in ventilated patient resulted in trend to decreased ICU-days compared to JN and MDI-AV. Aerosol-delivery with or without humidification did not have any significant effect on any of parameters studied. However, we recommend increasing the number of patients studied to corroborate this finding.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Pulmonary Pharmacology & Therapeutics - Volume 45, August 2017, Pages 40-46
نویسندگان
, , , , , , ,