کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5628205 1579819 2017 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
ReviewGoing down the tubes! Impact on seizure control of antiepileptic medication given via percutaneous feeding tubes
ترجمه فارسی عنوان
مرور کردن لوله ها! تأثیر در کنترل تشنج از داروهای ضد صرعی که از طریق لوله های تغذیه از طریق پوست دریافت می شود
کلمات کلیدی
گیره، تغذیه انتروال، جذب دارو صرع،
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب رفتاری
چکیده انگلیسی


- Administering AEDs via PEG has complex interactions influencing seizure control.
- Absorption site, excipients, and bioavailability significantly influence AED outcomes.
- AED interaction with nutritional feed and PEG type can also determine AED efficacy.
- In PWE and PEG, numerous factors affect AED delivery and are poorly researched.
- This vulnerable group of PWE is best managed by a multidisciplinary team approach.

BackgroundLong-term feeding by percutaneous endoscopic gastrostomy tube (PEG) is uncommon but can present significant issues when both nutrition and medication have to be fed down the same tube. This is especially important in people with epilepsy where the dose and bioavailability of antiepileptic drugs are critical to maintain adequate seizure control. This group with long-term PEG tubes is particularly vulnerable and dependent on their carers to provide high standard of care. Indeed, approximately half of the people with long-term feeding tubes suffer from severe intellectual disability which requires careful coordination of all members of the multidisciplinary team. It is all the more important when consideration is given that around 50% of people with severe ID have seizures, mostly treatment resistant.MethodA detailed literature review was conducted with the focus on the numerous factors that can affect medication delivery and absorption with the potential to destabilize seizure control in people with PEG. Issues concerning the site of drug absorption, excipients and dilution, interaction between antiepileptic drugs and the nutritional feed, bioavailability, and problems with the PEG tube are considered.ResultsThere is limited research in this area and the studies are often based on small numbers, healthy volunteers or in vitro findings.ConclusionIn the absence of sound research data, seizure control in each patient with a PEG needs to be considered on an individual basis. Establishing a baseline by measuring the serum levels prior to the tube insertion may be helpful, followed by checking the levels after PEG insertion.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Epilepsy & Behavior - Volume 74, September 2017, Pages 114-118
نویسندگان
, , , , ,