- Combination of a hand-held probe (HHF-probe) and a surgical microscope (FGR-microscope) was evaluated for fluorescence detection during surgery.
- The HHF-probe was superior to the FGR-microscope in sensitivity.
- The threshold for the analysis of the quantitative HHF-probe data can be adjusted to achieve a compromise between sensitivity and specificity.
- The combination of the HHF-probe and the FGR-microscope was beneficial in the tumor marginal zone.
BackgroundVisualization of the tumor is crucial for differentiating malignant tissue from healthy brain during surgery, especially in the tumor marginal zone. The aim of the study was to introduce a fluorescence spectroscopy-based hand-held probe (HHF-probe) for tumor identification in combination with the fluorescence guided resection surgical microscope (FGR-microscope), and evaluate them in terms of diagnostic performance and practical aspects of fluorescence detection.Material and MethodsEighteen operations were performed on 16 patients with suspected high-grade glioma. The HHF-probe and the FGR-microscope were used for detection of protoporphyrin (PpIX) fluorescence induced by 5-aminolevulinic acid (5-ALA) and evaluated against histopathological analysis and visual grading done through the FGR-microscope by the surgeon. A ratio of PpIX fluorescence intensity to the autofluorescence intensity (fluorescence ratio) was used to quantify the spectra detected by the probe.ResultsFluorescence ratio medians (range 0 - 40) measured by the probe were related to the intensity of the fluorescence in the FGR-microscope, categorized as “none” (0.3, n = 131), “weak” (1.6, n = 34) and “strong” (5.4, n = 28). Of 131 “none” points in the FGR-microscope, 88 (67%) exhibited fluorescence with the HHF-probe. For the tumor marginal zone, the area under the receiver operator characteristics (ROC) curve was 0.49 for the FGR-microscope and 0.65 for the HHF-probe.ConclusionsThe probe was integrated in the established routine of tumor resection using the FGR-microscope. The HHF-probe was superior to the FGR-microscope in sensitivity; it detected tumor remnants after debulking under the FGR-microscope. The combination of the HHF-probe and the FGR-microscope was beneficial especially in the tumor marginal zone.
Journal: Photodiagnosis and Photodynamic Therapy - Volume 18, June 2017, Pages 185-192