کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5856731 1131981 2015 15 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A practical application of two in silico systems for identification of potentially mutagenic impurities
ترجمه فارسی عنوان
کاربرد عملی دو در سیستم های سیلیکون برای شناسایی ناخالصی های موتاژنیک بالقوه
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست بهداشت، سم شناسی و جهش زایی
چکیده انگلیسی


- ICH M7 guidelines suggest to use two in silico systems for hazard identification.
- Evaluation of several in silico systems shows comparable predictive accuracy.
- When combining systems, nearly one third of predictions were contradictory.
- Expert review is demonstrated to significantly enhance predictive performance.
- Purity of the test article considered when building or evaluating in silico models.

The International Conference on Harmonization (ICH) M7 guidance for the assessment and control of DNA reactive impurities in pharmaceutical products includes the use of in silico prediction systems as part of the hazard identification and risk assessment strategy. This is the first internationally agreed guidance document to include the use of these types of approaches. The guideline requires the use of two complementary approaches, an expert rule-based method and a statistical algorithm. In addition, the guidance states that the output from these computer-based assessments can be reviewed using expert knowledge to provide additional support or resolve conflicting predictions. This approach is designed to maximize the sensitivity for correctly identifying DNA reactive compounds while providing a framework to reduce the number of compounds that need to be synthesized, purified and subsequently tested in an Ames assay. Using a data set of 801 chemicals and pharmaceutical intermediates, we have examined the relative predictive performances of some popular commercial in silico systems that are in common use across the pharmaceutical industry. The overall accuracy of each of these systems was fairly comparable ranging from 68% to 73%; however, the sensitivity of each system (i.e. how many Ames positive compounds are correctly identified) varied much more dramatically from 48% to 68%. We have explored how these systems can be combined under the ICH M7 guidance to enhance the detection of DNA reactive molecules. Finally, using four smaller sets of molecules, we have explored the value of expert knowledge in the review process, especially in cases where the two systems disagreed on their predictions, and the need for care when evaluating the predictions for large data sets.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Regulatory Toxicology and Pharmacology - Volume 72, Issue 2, July 2015, Pages 335-349
نویسندگان
, , , , , , , , , ,