کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5971224 1576183 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Current challenges for clinical trials of cardiovascular medical devices
ترجمه فارسی عنوان
چالش های کنونی برای آزمایش های بالینی دستگاه های پزشکی قلب و عروق
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی


- Double-blind, randomized, controlled trials are not feasible for some CV devices.
- The potential for bias should be considered in unblinded or nonrandomized trials.
- Measures should be taken to minimize bias to the extent possible.
- Alternative research approaches may be needed for evaluation of novel devices.

Several features of cardiovascular devices raise considerations for clinical trial conduct. Prospective, randomized, controlled trials remain the highest quality evidence for safety and effectiveness assessments, but, for instance, blinding may be challenging. In order to avoid bias and not confound data interpretation, the use of objective endpoints and blinding patients, study staff, core labs, and clinical endpoint committees to treatment assignment are helpful approaches. Anticipation of potential bias should be considered and planned for prospectively in a cardiovascular device trial. Prospective, single-arm studies (often referred to as registry studies) can provide additional data in some cases. They are subject to selection bias even when carefully designed; thus, they are generally not acceptable as the sole basis for pre-market approval of high risk cardiovascular devices. However, they complement the evidence base and fill the gaps unanswered by randomized trials. Registry studies present device safety and effectiveness in day-to-day clinical practice settings and detect rare adverse events in the post-market period. No single research design will be appropriate for every cardiovascular device or target patient population. The type of trial, appropriate control group, and optimal length of follow-up will depend on the specific device, its potential clinical benefits, the target patient population and the existence (or lack) of effective therapies, and its anticipated risks. Continued efforts on the part of investigators, the device industry, and government regulators are needed to reach the optimal approach for evaluating the safety and performance of innovative devices for the treatment of cardiovascular disease.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Cardiology - Volume 175, Issue 1, 15 July 2014, Pages 30-37