The Effect of Intermittent Atrial Tachyarrhythmia on Heart Failure or Death in Cardiac Resynchronization Therapy With Defibrillator Versus Implantable Cardioverter-Defibrillator Patients: A MADIT-CRT Substudy (Multicenter Automatic Defibrillator Implant
چکیده انگلیسی

ObjectivesThis study aimed to investigate the effect of both history of intermittent atrial tachyarrhythmias (IAT) and in-trial IAT on the risk of heart failure (HF) or death comparing cardiac resynchronization therapy with defibrillator (CRT-D) to implantable cardioverter-defibrillator (ICD) treatment in mildly symptomatic HF patients with left bundle branch block (LBBB).BackgroundLimited data exist regarding the benefit of CRT-D in patients with IAT.MethodsThe benefit of CRT-D in reducing the risk of HF/death was evaluated using multivariate Cox models incorporating the presence of, respectively, a history of IAT at baseline and time-dependent development of in-trial IAT during follow-up in 1,264 patients with LBBB enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study.ResultsThe overall beneficial effect of CRT-D versus ICD on the risk of HF/death was not significantly different between LBBB patients with or without history of IAT (HR: 0.50, p = 0.028, and HR: 0.46, p < 0.001, respectively; p for interaction = 0.79). Among patients who had in-trial IAT, CRT-D was associated with a significant 57% reduction in the risk of HF/death compared with ICD-only therapy (HR: 0.43, p = 0.047), similar to the effect of the device among patients who did not have IAT (HR: 0.47, p < 0.001; p for interaction = 0.85). The percentage of patients with biventricular pacing ≥92% was similar in both groups (p = 0.43). Consistent results were shown for the benefit of CRT-D among patients who had in-trial atrial fibrillation/flutter (HR: 0.30, p = 0.027; p for interaction = 0.41).ConclusionsIn the MADIT-CRT study, the clinical benefit of CRT-D in LBBB patients was not attenuated by prior history of IAT or by the development of in-trial atrial tachyarrhythmias. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy; NCT00180271)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 63, Issue 12, 1 April 2014, Pages 1190-1197
نویسندگان
, , , , , , , , , , , , ,