کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6053933 1197433 2011 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Basic ResearchComparison of Intracanal EndoSequence Root Repair Material and ProRoot MTA to Induce pH Changes in Simulated Root Resorption Defects over 4 Weeks in Matched Pairs of Human Teeth
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
Basic ResearchComparison of Intracanal EndoSequence Root Repair Material and ProRoot MTA to Induce pH Changes in Simulated Root Resorption Defects over 4 Weeks in Matched Pairs of Human Teeth
چکیده انگلیسی

IntroductionIntracanal mineral trioxide aggregate (MTA) may provide an alternative to calcium hydroxide in the treatment of external inflammatory root resorption. This in vitro study using human matched pairs of teeth compared white ProRoot MTA (WMTA; (Dentsply Tulsa Dental Specialties, Tulsa, OK) and an alternative material with purportedly improved handling properties, EndoSequence Root Repair Material (ES; Brasseler USA, Savannah, GA), by measuring pH in simulated root surface resorptive defects after intracanal placement. The null hypothesis tested was that there is no difference between WMTA and ES.MethodsBilaterally matched pairs (n = 24) of extracted, human, single-rooted teeth were instrumented to apical size 50/.06, and root surface cavities were prepared at 5 mm and 2 mm from the apex. Root canals of experimental matched pairs (n = 20) were filled with WMTA or ES; control pairs (n = 4) were filled with calcium hydroxide (positive control [POS]) or saline (negative control [NEG]). Teeth were sealed coronally and apically and immersed in saline. The pH in root surface cavities was measured at 20 minutes, 3 hours, 24 hours, 1 week, 2 weeks, 3 weeks, and 4 weeks.ResultsThe pH at 5 mm when compared with the 2-mm level was significantly higher for the WMTA, ES, and POS groups (P < .05, paired t tests); therefore, each level was analyzed separately. At both the 2-mm and 5-mm levels, significant pH changes occurred over time in the WMTA, ES (both P < .0001, repeated-measures analysis of variance), and POS (P < .0001, Friedman test) groups and not in the NEG group (mean pH = 7.32 ± 0.04, P > .05). There were no differences between WMTA and ES at 20 minutes and 3 hours at both levels or at 24 hours at 5mm. The pH of WMTA was higher than ES by 24 hours at the 2-mm level (8.79 vs 8.56, P < .05, paired t test) and after 1 week at the 5-mm level (8.91 vs 8.05, P < .0001) and was thereafter always significantly higher in WMTA compared with ES (P < .0001). The null hypothesis was rejected.ConclusionsIn matched pairs of teeth, intracanal placement of WMTA compared with ES resulted in a higher pH in simulated root resorption defects that was time and root level dependent.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Endodontics - Volume 37, Issue 4, April 2011, Pages 502-506
نویسندگان
, , , , ,