BackgroundNo consensus on how to best predict for chest wall injury following SABR exists. We report our experience in chest wall dose assessment when treating peri-pleural lung lesions with stereotactic ablative radiotherapy (SABR) delivered with volumetric modulated arc therapy (VMAT).Methods40 patients with peri-pleural peripheral lung tumors underwent SABR between July, 2012 and February, 2015. Chest wall toxicity, dose distribution, and the influence of chest wall delineation method were investigated.ResultsAfter a median follow up of 16 months, no rib fracture or skin toxicity was observed. 4 patients (10%) reported persistent chest wall pain (grade 1-2). High dose rate's association with chest wall pain trended toward statistical significance (p=0.06). PTV exclusion and reducing chest wall expansion to 1Â cm led to significant dose reduction in the chest wall dose volume parameters (p<0.05). Only three local failures were observed among 44 lesions treated.ConclusionsThe risk of chest wall pain following SABR delivered with VMAT is low. High dose rate, which is 1400Â MU/min with flattening filter free (FFF) beams vs. 500-600Â MU/min with non-flattening filter free (non-FFF) beams, may contribute to it. Chest wall dose volume parameters may vary with PTV exclusion; while chest wall expansion of 1Â cm may fail to account for some high dose regions in the chest wall.
Journal: Cancer Treatment and Research Communications - Volume 9, 2016, Pages 5-14